An old sewage system of several pits: what happens before the odour appears
In many houses, guest houses and small cafés the sewage system is arranged the same way: a first concrete tank with a bottom, followed by one or more bottomless pits through which the water soaks into the ground. For years such a system needs no attention, and people remember it when an odour appears. But odour is a late signal: by that point the inside holds what has been accumulating for many years.
What this scheme can and cannot do
The first tank works as a settler. Heavy particles sink, fat and light matter float, and the clarified water passes on. The bottomless pits take this water and release it into the ground. In essence this is a holding and soakaway septic system: it retains part of the suspended solids and removes the need to haul wastewater away.
There is almost no biological treatment here. Dissolved organic matter, ammonium and microorganisms go into the ground with the water. There is no oxygen in the closed chambers, so everything that breaks down in them breaks down anaerobically, that is, without oxygen. Such a scheme can cope with the domestic load of a small house for years, but it is not designed for a restaurant kitchen, a laundry or a seasonal flow of guests.
The scheme is particularly sensitive to fat. Warm fat from the kitchen travels along the pipe, cools in the first tank and floats up, but part of it leaves as an emulsion and settles on the walls of the pits. Detergents and washing powders keep fat emulsified longer, so a kitchen and a laundry together load the pits more heavily than either of them alone.
What builds up inside and why the ground stops taking water
Sediment accumulates in the first tank all the time. The higher the sludge layer and the thicker the grease crust, the smaller the working volume between them and the less time the water spends in the settler. At some point particles no longer have time to settle and move on into the next pits.
That is where the main hidden problem begins — clogging, that is, the blocking of the pores of the soil. Suspended solids and fat settle on the bottom and walls of the bottomless pits, a dense biofilm grows on the soil surface, and water passes through it more and more slowly. As long as the absorbing area is larger than needed, this goes unnoticed. When the margin runs out, the level in the pits rises, the water stands longer and therefore stays without oxygen longer. The rate of clogging depends on the soil: in sand and gravel the margin is usually larger, in loam and clay smaller, and pits in heavy soils lose their absorbing capacity noticeably faster.
Long residence without oxygen is a condition for sulfate reduction, in which bacteria reduce sulfate to sulfide and hydrogen sulfide. This mechanism is covered in more detail in the article on dissolved oxygen and odour at a treatment plant. At first the hydrogen sulfide stays dissolved in the water and under the pit covers, and it escapes when there is a lot of it or when conditions change: hot weather, a peak discharge, an open hatch.
Signs that appear before the odour
The system usually gives signals long before the odour becomes constant. The following signs are worth watching:
- ✓the level in the pits drops more slowly after a discharge than it used to
- ✓after a peak discharge the water stands higher than usual or reaches the hatch
- ✓the first tank has a thick grease crust or sludge almost up to the overflow
- ✓toilets and floor drains empty more slowly, especially on the ground floor
- ✓a faint odour appears in the evening, in hot weather or after laundry
- ✓the ground around the pits is damp or sinking
- ✓the sludge has not been pumped out for several years or the date is unknown
- ✓the load has grown: rooms, a kitchen or a laundry have been added
Each sign on its own may have another cause, but two or three together usually mean that the reserve of volume and absorbing capacity has been used up.
Pumping out the sludge is the first step, but not always the last
Pumping excess sediment out of the first tank is a simple and often effective first step. It restores the working volume, increases settling time, removes the main source of hydrogen sulfide and reduces the carry-over of solids into the pits. The sludge level is checked with a pole or a sampler: if the sludge and crust together take up about a third of the depth or more, the pump-out is not postponed. A small part of the sediment is left behind so that decomposition does not start from zero. After pumping out it is worth recording the date and the layer thickness: a repeat measurement a year or two later will show the rate of accumulation and allow maintenance to be planned in advance rather than in response to an odour.
Pumping out does not help if the bottomless pits are already clogged: the tank quickly fills again because the water has nowhere to go. Nor does it solve constant overload, for example when a restaurant kitchen without a grease trap has been connected to a domestic scheme. Sometimes pumping out is technically difficult: large tanks, dense compacted sediment, no access for the truck. Then the odour is held back temporarily by shifting the environment from sulfate reduction to an anoxic regime through dosing a nitrate-containing reagent, but this is a temporary measure, not a solution.
Keep, convert or replace
The decision depends on the condition of the tanks and on what the site needs. If the shell of the first tank is intact and its volume matches the flow, it can often be converted: an aerated zone with circulation and a settling zone are separated, and the settler becomes biological treatment. How this works and where the approach reaches its limit is described in the article on septic tank retrofit and on the page of the SOLVIA Retrofit Module development.
If the shell is damaged, the volume is clearly too small for the load, or the pits are so clogged that the ground no longer takes water, a conversion does not pay off, and it is more sensible to install a biological treatment plant with a new discharge arrangement. How such a plant works is covered in the article on the zones of a deep biological treatment plant. If the site plans to expand, the decision is made for the future load rather than the current one: a scheme sized with no margin will have to be rebuilt again in a few years.
A separate word about a common do-it-yourself fix — lowering a compressor with an aerator into the old tank. Without removing the old sludge and without a settling zone, the air stirs up the sediment, strips dissolved hydrogen sulfide into the air and increases the carry-over of solids into the pits, that is, it speeds up their clogging.
What next
To assess an old system, collect some simple data: the number of tanks and pits, the dimensions and depth of each, whether they have a bottom, the water level and sludge layer in the first tank, and the date of the last pump-out. Add the type of site, the number of residents or guests, whether there is a kitchen, a grease trap and a laundry, and a description of where and when the odour appears and how quickly the water drains. Take photos of the hatches and the plot. This data shows whether pumping out and regular maintenance will be enough or whether the system needs rebuilding. Ready-made biological treatment plants are collected in the septic tanks for the home section.