DAF-60, capacity 55–60 m³/h
In the middle of the line, a compressor is part of the unit, and the power of the agitators and the scraper rises step by step: the machine is designed for a steady flow with a high content of fats and suspended solids, not for occasional discharges. The recirculation scheme — part of the treated water is returned to the pressure line — keeps air saturation stable under a changing load.
Typical sites: meat and fish processing, dairy production, food industry enterprises. Here the flotation unit reduces the load on the biological stage and recovers valuable raw material from process water.
From the piping, such units require equalization of the effluent before it is fed in and an organized discharge of flotation sludge: skimming is adjusted to the actual amount of sludge, and operation is automatic, with remote monitoring.
DAF-60 version: capacity 55–60 m³/h, drive power 7.5 kW, dimensions 9000×2500×2500 mm, pressurized water flow rate 25 m³/h.
By capacity it sits between DAF-50 (45–50 m³/h) and DAF-75 (70–75 m³/h): 55–60 m³/h. Pressurized water flow rate 25 m³/h — the same as on DAF-50. Drive power 7.5 kW — the same as on DAF-50 and DAF-40. Compressor power 4 kW against 3 kW on DAF-100.
One step down by capacity — DAF-50: scraper power 0.75 kW instead of 1.1 kW, dimensions 9000×2150×2150 mm instead of 9000×2500×2500 mm. One step up — DAF-75: mixer power 0.75×3 kW instead of 0.75×2 kW, dimensions 9000×3000×3000 mm instead of 9000×2500×2500 mm.
Tell us about your site — our engineer will prepare a process design, a specification and a quotation within one business day.